FOR ARCHITECTS

While projecting new buildings, it is compulsory to gather all the most needed data just like prospective elevators shaft’s dimensions along with elevator’s (or escalator’s, ramp’s, walkway’s) functionality.

Seeking to make the process of projecting easier, we are always ready to provide detailed schemes of particular elevators. Most of the architects find our cooperation valuable.

Wide production range we offer, the possibilities of suggested elevator’s cabins allow creating an exclusive interior of a building. Technologies used for elevators allow them to become a focal element of an interior design, keeping the general line of precision.

ORONA 3G cabin’s design catalog 

Technical decisions of elevators engineering allow installing the same elevator models in various buildings serving different purposes. Considering the specification of the project as well as individual needs (medical buildings, hotels, offices, and the need for freight loading in other types of buildings), different kinds of variations might be chosen. The unique and individual decision is made combining cabin, doors, and other parameters. Each decision offered for the precision of the architect’s project.

Cabins and doors dimensions’ requirements of elevators for the disabled – ISO 21542:2011.  

ORONA 3G technical facilities

Model Description Maximum lifting capacity Maximum lifting height/stopping times Standard elevator’s schemes 
3G_X10 Modest hight, low-level lifting capacity elevator;  An elevator for offices’ building; hotels; dwelling-houses, when the shaft is adjusted ahead. Well standardized solution. 630 kg /
8 individuals
45 m / 16 Standard 
Passable in 90 degrees angle (does not correspond to ISO 21542:2011, q.v. model X19) 
Passable in 180 degrees angle
3G_X11 The existing modest building; the case when due to cultural heritage requirements or in case of the building’s ground qualities the depth of the elevator’s pit must be resized (up to 310 mm). 630 kg /
8 individuals
45 m / 16  
3G_X14 The existing modest building; the case when due to existing shaft qualities, the minimal space decision is needed while installing as spacious cabin as possible.  630 kg /
8 individuals
 45 m / 16  
3G_X15 The bigger building having more space; a large flow of individuals; in case a spacious, more powerful, and the stretcher-fitting elevator is needed. 1000 kg /
13 individuals
 60 m / 21 Standard
Passable in 180 degrees angle
3G_X16 Medical institutions, hospitals, and big administrative buildings of another nature, where a powerful, spacious, and reliable elevator is needed.  1600 kg /
21 individuals
 75 m / 32 Standard
3G_X18 Medical institutions, hospitals, and big administrative buildings of another nature, where a powerful, spacious, and reliable elevator is needed.  2500 kg /
33 individuals
 75 m / 32  
3G_X19 The building with a large glow of individuals or with a need to lift the disabled. Elevator with multiple doors installed at 90 degrees angle.  1250 kg /
16 individuals
 40 m / 16 Passable in 90 degrees angle
3G_X24 Renovated apartment house or dwelling-house with an old elevator and machines room.  630 kg /
8 individuals
 45 m / 16 Standard
3G_X27 Very large building/skyscraper having big flows of individuals; requiring an elevator of great capacity and power.  1000 kg /
13 individuals
130 m / 46